| Name | 
                    Information | 
                  
                  
                    
                      | Code: | 
                      T108 | 
                    
                  
                  
                    
                      | Test Name, Short: | 
                      HCV | 
                    
                  
                  
                  
                    
                      | Matrix: | 
                      Serum, potassium EDTA plasma, lithium or sodium heparinized plasma are the recommended sample types for this assay | 
                    
   
                
                  
                    
                      | Turnaround Time: | 
                      Daily | 
                    
                  
                  
                  
                    
                      | Analytical Method: | 
                      HCV assay is an indirect two wash sandwich immunoassay | 
                    
                  
                  
                    
                      | Reportable - Test Results Type: | 
                      The system reports anti-HCV results in Index Values and as reactive, nonreactive, or equivocal. Index values above the cutoff of the assay are not indicative of the antibody level present in the sample. • Samples with a calculated value of less than 0.80 Index Value are considered nonreactive (negative) for IgG antibodies to HCV. • Samples with a calculated value greater than or equal to 0.80 Index Value and less than 1.00 Index Value are considered equivocal. It is recommended that the sample be repeated in duplicate. If 2 of the 3 sample results are less than 0.80 Index Value, the sample is considered nonreactive. If 2 of the 3 sample results are greater than or equal to 1.00 Index Value, the sample is considered reactive and supplemental testing of the sample is recommended. If 2 of the 3 sample results are greater than or equal to 0.80 Index Value and less than 1.00 Index Value, supplemental testing of the sample is recommended. • Samples with a calculated value greater than or equal to 1.00 Index Value are considered reactive for IgG antibodies to HCV. | 
                    
                  
                  
                    
                      | Units - Conventional: | 
                      The system reports anti-HCV results in Index Values and as reactive, nonreactive, or equivocal. Index values above the cutoff of the assay are not indicative of the antibody level present in the sample. • Samples with a calculated value of less than 0.80 Index Value are considered nonreactive (negative) for IgG antibodies to HCV. • Samples with a calculated value greater than or equal to 0.80 Index Value and less than 1.00 Index Value are considered equivocal. It is recommended that the sample be repeated in duplicate. If 2 of the 3 sample results are less than 0.80 Index Value, the sample is considered nonreactive. If 2 of the 3 sample results are greater than or equal to 1.00 Index Value, the sample is considered reactive and supplemental testing of the sample is recommended. If 2 of the 3 sample results are greater than or equal to 0.80 Index Value and less than 1.00 Index Value, supplemental testing of the sample is recommended. • Samples with a calculated value greater than or equal to 1.00 Index Value are considered reactive for IgG antibodies to HCV |